The September 2002 Version of the Method 1600 Enterococcus Test: Aerococcus viridans as a False-positive Organism: Research Project Summary

dc.contributor.authorFeerst, Eric
dc.contributor.authorHovendon, Bruce
dc.contributor.authorAtherholt, Thomas
dc.date.accessioned2020-12-03T17:10:05Z
dc.date.available2020-12-03T17:10:05Z
dc.date.issued2007
dc.description.abstractWhen analyzing marine bathing water samples using the September 2002 version of the USEPA Method 1600enterococcus test, Aerococcus viridans was infrequently observed as a high-rate “false-positive” organism. The USEPA intends to revise Method 1600 to eliminate the counting of blue-halo colonies less than 0.5 mm diameter, but users of the September 2002 or earlier version of Method 1600 should be aware of this false-positive issue.en_US
dc.identifier.urihttps://hdl.handle.net/10929/68796
dc.language.isoen_USen_US
dc.publisherTrenton, N.J. : New Jersey Department of Environmental Protection, Division of Science, Research and Technologyen_US
dc.subjectNew Jerseyen_US
dc.titleThe September 2002 Version of the Method 1600 Enterococcus Test: Aerococcus viridans as a False-positive Organism: Research Project Summaryen_US