The September 2002 Version of the Method 1600 Enterococcus Test: Aerococcus viridans as a False-positive Organism: Research Project Summary
dc.contributor.author | Feerst, Eric | |
dc.contributor.author | Hovendon, Bruce | |
dc.contributor.author | Atherholt, Thomas | |
dc.date.accessioned | 2020-12-03T17:10:05Z | |
dc.date.available | 2020-12-03T17:10:05Z | |
dc.date.issued | 2007 | |
dc.description.abstract | When analyzing marine bathing water samples using the September 2002 version of the USEPA Method 1600enterococcus test, Aerococcus viridans was infrequently observed as a high-rate “false-positive” organism. The USEPA intends to revise Method 1600 to eliminate the counting of blue-halo colonies less than 0.5 mm diameter, but users of the September 2002 or earlier version of Method 1600 should be aware of this false-positive issue. | en_US |
dc.identifier.uri | https://hdl.handle.net/10929/68796 | |
dc.language.iso | en_US | en_US |
dc.publisher | Trenton, N.J. : New Jersey Department of Environmental Protection, Division of Science, Research and Technology | en_US |
dc.subject | New Jersey | en_US |
dc.title | The September 2002 Version of the Method 1600 Enterococcus Test: Aerococcus viridans as a False-positive Organism: Research Project Summary | en_US |
dc.type | Article | en_US |